WJ-90 Laboratory Micromotor System
Our laboratory range includes 35,000 and 50,000 RPM options. Specify the speed, voltage and accessories required for your order.
- 35,000 / 50,000 RPM
- 110V / 220V
- Noise ≤65 dB
HYDRUMP WJ-90 laboratory systems support extraoral grinding, polishing, trimming and finishing workflows.
Explore our dental lab handpiece systems, three handle models and foot-control option. Contact our team for laboratory purchasing and distributor orders.

A dental lab handpiece is a motor-driven rotary tool holder used for extraoral laboratory work. A controller supplies power and sets the motor speed; the handle drives the selected grinding, polishing or finishing tool.
Laboratory equipment is distinct from intraoral clinical handpieces. Select it for work outside the patient’s mouth, not as a substitute for a chairside instrument.
The controller supplies power to the motor-driven handle. Its speed dial sets the requested rotation speed.
The powered handle holds and rotates the tool. It is a separate component from the controller.
Specify pedal WJ-90-102-317 when foot control is required. Include it as a separate item in your inquiry.
Select the working tool for the task and match its shank requirements and speed limit to the handle and motor.
Specify the controller, handle and pedal as separate line items when discussing a system or replacement order.
Start with the WJ-90 laboratory system, then use the accessory model and item numbers to specify the components required for your order.
Our laboratory range includes 35,000 and 50,000 RPM options. WJ-90 item 130021 is the 35,000 RPM unit. Specify your required speed when requesting a quotation.
Request WJ-90 / 130021 and include the input voltage and handle model.
Send us your voltage, handle and control requirements so we can check the corresponding 50,000 RPM unit for your quotation.
Choose the working speed for your task and stay within the handle and rotary tool limits. RPM alone does not indicate torque or cutting performance.
The operating environment and intended task determine which category to purchase.
| Selection factor | Laboratory Handpiece | Clinical Dental Handpiece |
|---|---|---|
| Primary Use | Extraoral laboratory work | Chairside procedures within the selected product’s intended use |
| Drive System | Micromotor / laboratory motor systems | Air turbine or clinical electric motor |
| Typical Workflows | Grinding, polishing, trimming, finishing | Category-specific restorative, surgical, implant or polishing procedures |
| Environment | Dental laboratory | Dental clinic / treatment setting |
| Selection Priority | Speed range, handle, control method, voltage | Procedure, connection, speed, torque, spray and sterilization requirements |
For chairside categories, see high-speed dental handpieces, low-speed dental handpieces and electric dental handpieces.
Use the model and item numbers below for system quotations or replacement parts. For a replacement, send us the existing controller and handle labels so we can check the match.
| Product | Model / Number | Speed | Input | Noise | Component References |
|---|---|---|---|---|---|
| Laboratory micromotor | WJ-90 series | 35,000 / 50,000 RPM | 110V / 220V | ≤65 dB | 102 / 18 / 204 handles; WJ-90-102-317 pedal. Supply list specified in the quotation. |
| Portable Micro Motor (related option) | 130032 | 2,000–40,000 RPM | DC 24V | ≤60 dB | Contact us for the supply list. |
Portable Micro Motor torque: 3.4 N·cm. WJ-90 torque and noise test conditions are not published here; contact our team if your specification requires these details.
Before Ordering: Send us your speed, voltage, handle, rotary tool and control requirements. The quotation should specify the controller–handle pairing, pedal function and included components. Do not assume the three handles are interchangeable. Request operating instructions for the selected model.
Use these five checkpoints to prepare a dental lab handpiece purchase request.
State 35,000 or 50,000 RPM in the inquiry and include the rotary tool’s operating speed limit.
Specify 110V or 220V for the WJ-90 laboratory series. Match the ordered unit to the destination power supply.
Choose a quotation reference: WJ-90-102 / 130003, WJ-90-18 / 130004 or WJ-90-204 / 130009. For replacement inquiries, include the existing controller and handle labels.
State whether foot control is required and list pedal WJ-90-102-317 in the request. Ask for an itemized controller, handle and accessory list.
Describe the extraoral laboratory task and rotary tool. Request the selected model’s operating instructions before purchase.
Select the rotary tool for the task and state the working speed in your inquiry.

WJ-90 / 130021 is our 35,000 RPM laboratory unit. Use the series specifications below to prepare your inquiry, including the required voltage and full accessory references.
For a WJ-90 quotation, state the speed and voltage first, followed by the handle reference, pedal requirement and quantity.
Request WJ-90 PricingWe have manufactured dental handpieces since 2006. Our range includes high-speed, low-speed and motor-driven systems.
Our team supports product selection and pricing inquiries from dental laboratories and distributors.
About HYDRUMPSend the required speed, input voltage, handle model, foot-control requirement, quantity and destination market. For replacement parts, include photos of the controller and handle labels and their connectors. This helps us identify the requested configuration and prepare an itemized quotation.
This range is for extraoral laboratory grinding, polishing, trimming and finishing. It is separate from our clinical handpieces for patient treatment. Tell us the task and rotary tool you use so we can review the intended application with you.
The supply list is specified in your quotation. Tell us whether you need a complete system, a handle or a pedal, and check each included item before ordering. The three handle models and foot pedal are separate references, not evidence of one standard bundle.
Choose the working speed required by your tool and task. WJ-90 / 130021 is the 35,000 RPM unit; for 50,000 RPM, we need to check the corresponding model and item number. Higher RPM alone does not mean higher torque or better cutting performance.
Our laboratory range includes 110V and 220V options. Specify the voltage, destination country and any plug or frequency requirements when requesting a quotation. These options do not establish automatic voltage switching; check the quoted unit’s input rating before connecting it.
102 Handle: WJ-90-102, item 130003. 18 Handle: WJ-90-18, item 130004. 204 Handle: WJ-90-204, item 130009. Use both model and item number in your inquiry to identify the handle you need.
Do not assume the 102, 18 and 204 handles are interchangeable. Send us the controller model, handle label and connector photos so we can check the pairing. The model names alone do not establish electrical or mechanical compatibility.
Send the tool’s shank diameter, tool type and rated maximum speed, together with the handle model. We need to check the chuck interface and operating limits; a universal shank size or tool compatibility is not specified for these handles.
Specify WJ-90-102-317 if you need foot control. Tell us whether you require start/stop operation, speed adjustment or both. We will check the function and controller pairing for the quoted unit; do not assume either mode from the pedal photograph.
Request the operating and maintenance instructions for the exact handle and controller. Use those instructions to establish cleaning, lubrication and servicing requirements. Do not apply a clinical handpiece’s autoclave or immersion routine to this equipment without explicit model-specific instructions.
A maximum RPM rating does not establish continuous-duty capability. Tell us the task, tool, working speed and expected operating duration so we can review the required duty cycle and load information. WJ-90 torque-under-load and continuous-operation limits are not published on this page.
≤65 dB is the laboratory-series noise specification. Measurement distance, load and other test conditions are not stated here, so it is not a promise of the same sound level at every workstation. Contact us if your purchasing specification requires a defined noise test.
130032 is a separate product rated at 2,000–40,000 RPM, 3.4 N·cm, DC 24V and ≤60 dB. These values do not establish compatibility with the WJ-90 handles or suitability for your laboratory task. Contact us to check its intended use and interfaces before selecting it.
Send the model, configuration, quantity and destination. We can review sample availability, minimum order quantity, pricing and lead time for that request. No fixed sample policy, minimum quantity or delivery schedule is offered on this page; obtain the applicable terms with your quotation.
Ask us for the written warranty, service scope and replacement-parts terms for the quoted model and destination market. Include the product label, order reference and fault details in a service inquiry. Warranty duration and local service arrangements are not specified on this page.
Send your WJ-90 speed, voltage, handle and pedal requirements, quantities and destination market for configuration and B2B pricing.